The main tower of capacitance
source: /upload/2020-04-28/2818051821.jpg Release time:2020-04-28
USES:
The main capacitor tower ACTS as a pre-charged capacitor bank for the test circuit to provide a synthetic test voltage, and is used to provide instantaneous large amounts of energy in the test circuit of the high-voltage circuit breaker. The power frequency voltage obtained by the short-time oscillating discharge of the power frequency reactor, the short-circuit current of higher frequency obtained by adjusting the oscillating discharge of the reactor, and the working condition of the circuit breaker breaking short-circuit fault current.
Main technical performance and parameters:
● rated voltage/capacitance of a single capacitor: 100kV/3uF
● Test grade: 40.5kv ~ 252kV